AV
- REACH
- RoHS
- CE
- CPR Compliant
AV – Standard wall PVC insulation
Application
These are standard wall auto cables for ideal use in automotives by harness manufacturers.
Standards
In accordance to JASO D 611, JASO D 618, JIS C 3406
Temperature Range (3000 Hrs)
-40°C to +80°C
Cable Construction
Soft annealed electrolytic copper Cu-ETP1 according to D 609-90, bare conductor construction according to JASO D 611
PVC insulation, material accordingly to JASO D 611
Packing
Available in 100 mtrs. Longer length available in spools.
Cabel Design Parameters
Nom.
Cross-Section (mm²) | No. of
Strands | Max. Strand
Diameter (mm) | Max.
Conductor Diameter (mm) | Max. DC
Conductor Resistance at 20°C (Ω/km) | Min. Insulation
Thickness (mm) | Overall Diameter (mm) | Approx. Weight
(Kg/Km) |
|
Max. | Tolerance | |||||||
0.5 | 7 | 0.32 | 1.0 | 32.7 | 0.6 | 2.4 | -0.2 | 10.0 |
0.85 | 11 | 0.32 | 1.2 | 20.8 | 0.6 | 2.6 | -0.2 | 13.0 |
1.25 | 16 | 0.32 | 1.5 | 14.3 | 0.6 | 2.9 | -0.2 | 17.0 |
2 | 26 | 0.32 | 1.9 | 8.81 | 0.6 | 3.4 | -0.3 | 26.0 |
3 | 41 | 0.32 | 2.4 | 5.59 | 0.7 | 4.1 | -0.3 | 40.0 |
5 | 65 | 0.32 | 3.0 | 3.52 | 0.8 | 4.9 | -0.3 | 62.0 |
8 | 50 | 0.45 | 3.7 | 2.32 | 0.9 | 5.8 | -0.3 | 92.0 |
10 | 63 | 0.45 | 4.5 | 1.84 | 1.0 | 6.9 | -0.4 | 120.0 |
15 | 84 | 0.45 | 4.8 | 1.38 | 1.1 | 7.4 | -0.4 | 160.0 |
0.5f* | 20 | 0.18 | 1.0 | 36.7 | 0.6 | 2.4 | -0.2 | 9.0 |
0.85f* | 30 | 0.18 | 1.2 | 24.4 | 0.6 | 2.6 | -0.2 | 12.0 |
1.25f* | 50 | 0.18 | 1.5 | 14.7 | 0.6 | 2.9 | -0.2 | 18.0 |
2f* | 37 | 0.26 | 1.8 | 9.5 | 0.6 | 3.4 | -0.4 | 25.0 |
3f* | 61 | 0.26 | 2.4 | 5.76 | 0.7 | 4.1 | -0.3 | 40.0 |