FLYW

  • REACH
  • RoHS
  • CE
  • CPR Compliant
cable-preview
cable-pack-preview
cable-inner-preview

Application

These are auto cables ideal for use in automotives with hot pressure resistance

Standards

In accordance to ISO 6722-1

Temperature Range (3000 Hrs)

-40°C to +125°C

Cable Construction

Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1

Soft PVC insulation with properties according to ISO 6722-1, Class C

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Special Properties

Hot pressure resistance test at 120°C. Suitable for applications inside the engine compartment.

Cabel Design Parameters

Nom.
Cross-Section
(mm²)
No. of
Strands
Max. Strand
Diameter (mm)
Max.
Conductor
Diameter (mm)
Max. DC
Conductor
Resistance
at 20°C (Ω/km)
Nominal
Insulation
Thickness (mm)
Overall Diameter (mm)Approx. Weight
(Kg/Km)
Max.Tolerance
0.5160.211.037.10.62.3-0.38.0
0.75240.211.224.70.62.5-0.311.0
1320.211.3518.50.62.7-0.314.0
1.25*160.331.714.90.62.95-0.5514.0
1.5300.261.712.70.63.0-0.319.0
2280.312.09.420.63.3-0.325.0
2.5500.262.27.60.73.6-0.331.0
3600.262.46.00.74.1-0.337.0
4560.312.754.710.84.4-0.447.0
5650.333.13.940.84.9-0.458.0
6840.313.33.140.85.0-0.468.0
8*500.464.32.380.85.9-0.988.0
10800.414.51.821.06.5-0.5111.0
12**960.415.41.521.07.4-0.8142.0
161260.416.31.161.08.3-0.6179.0
20**1520.416.90.9551.19.1-1.0218.0
251960.417.80.7431.310.4-1.0278.0
  • *Sizes from JIS C3406   **Not as per ISO 6722