PVC/PVC 3 CORE SUBMERSIBLE FLAT CABLE

  • REACH
  • RoHS
  • CE
  • CPR Compliant
cable-preview
cable-pack-preview
cable-inner-preview

Application

The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications. The sheath is specially made out to resist tough and difficult outdoor conditions & excellent resistant to water.

Technical Data

Approvals: IS 694 marked, FIA/TAC

Conductor: Electrolytic grade annealed copper

Core Colour: Red, yellow (centre core), blue

Conductor: Strands of electrolytic annealed plain copper are multi-drawn for uniformity of resistance, dimension and flexibility.

Sheath Colour: Black

Voltage Grade: Upto and including 1100V

Packing: Standard packing of 100 mtr. in coils. Longer length available on request.

Variants Available

Part NumberSpecifications
PVC 70°CIS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type A insulation & ST-1 sheath.
HR 85°CIS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type C insulation & ST-2 sheath.

Cabel Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the cable type
1 – PVC 70°C, 3 – PVC HR 85°C.

Part NumberConductor constructionConductor
resistance at 20 °C
(Ω/km) Max.
Nom. Insulation
thickness (mm)
Nominal Sheath
Thickness
(mm)
Approx. overall dimensions
(W X H) (mm) +/- 0.5 mm
Current carrying
capacity (Ampere)
Cross sectional
area (Sq. mm)
No./Max. dia of capacity (Ampere)
strands (mm)
0118110102y10.516/0.239.00.60.99.60 X 4.904
0118110202y10.7524/0.226.00.60.910.5 X 5.207
0118110302y1132/0.219.50.60.911.0 X 5.4012
0118110402y11.5*22/0.312.10.60.912.0 X 5.618
0118110502y12.5*36/0.37.410.71.013.0 X 6.224
0118110602y1456/0.34.950.81.015.3 X 7.128
0118110702y1684/0.33.300.81.119.2 X 8.436
0118110802y110140/0.31.911.01.424.2 X 10.448
0118110902y116126/0.41.211.01.429.0 X 12.464
0118111002y125196/0.40.781.22.036.5 X 15.780
0118111102y135276/0.40.5541.22.040.5 X 17.2100
0118111202y150396/0.40.3861.42.246.5 X 19.3130
0118111302y170360/0.50.2721.42.252.0 X 21.0192
0118111402y195480/0.50.2061.62.461.0 X 24.5230
  • For current ratings refer table no. 9-1, for voltage drop refer table no. 9-2.

Current rating conversion factor for deviating ambient temperature

Multiply the current carrying capacity of the cable by the factors given below for various ambient temperature.

Ambient Temperature (°C)Derating Factor
251.25
301.16
351.09
401.00
450.90
500.81
550.74
600.68