UL 3289/3321/3173/3271/3344 XLPE CABLE
- REACH
- RoHS
- CE
- CPR Compliant
Application
These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.
Technical Data
Standard: UL – Std. 758. Complies to CSA No. 22.2 210 and 127
Nominal Voltage: 600V
Test Voltage (Spark Test):
AWG 22 and 20: 5kV
AWG 18 to 10: 6kV
≥ AWG 8: 7.5kV
Temperature Range: Flexible -5°C to +150°C. Fixed installation -50°C to +150°C
Temperature at Conductor: Max. UL : +150°C
Bending Radius: Approx. 5 x cable ø
Cable Construction
- Annealed plain or tinned stranded copper conductor.
- XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.
Properties
- PVC self – extinguishing and flame retardant, test method to FT 2
Cable Design Parameters
AWG | Metric
Cross Section Area (Sq. mm) | No. of
Strands/Strand Dia. (mm) | Max. DC Conductor
Resistance for ABC @ 20°C (Ω/km) | Max. DC Conductor
Resistance for ATC @ 20°C (Ω/km) | Insulation
Thickness (mm) | Nominal Cable
Diameter (mm) |
21 | 0.50 | 16/0.2 | 43.6 | 46.9 | 0.762 | 2.4 |
19 | 0.75 | 24/0.2 | 27.4 | 29.1 | 0.762 | 2.6 |
18 | 1.00 | 32/0.2 | 21.8 | 23.2 | 0.762 | 2.8 |
16 | 1.50 | 30/0.25 | 13.7 | 14.6 | 0.762 | 3.1 |
14 | 2.50 | 50/0.25 | 8.62 | 8.96 | 0.762 | 3.5 |
12 | 4.00 | 56/0.3 | 5.43 | 5.64 | 0.762 | 4.0 |
10 | 6.00 | 84/0.3 | 3.409 | 3.546 | 0.762 | 4.6 |
8 | 10.00 | 140/0.3 | 2.144 | 2.23 | 1.143 | 6.1 |
6 | 16.00 | 126/0.4 | 1.348 | 1.403 | 1.524 | 7.9 |
4 | 25.00 | 196/0.4 | 0.8481 | 0.882 | 1.524 | 9.1 |
2 | 35.00 | 276/0.4 | 0.5335 | 0.5548 | 1.524 | 10.7 |
1 | 50.00 | 296/0.4 | 0.423 | 0.4398 | 2.032 | 12.8 |
2/0 | 70.00 | 360/0.5 | 0.266 | 0.2766 | 2.032 | 14.8 |
3/0 | 95.00 | 480/0.5 | 0.211 | 0.2194 | 2.032 | 16.2 |
4/0 | 120.00 | 608/0.5 | 0.1673 | 0.1722 | 2.032 | 17.7 |
Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue Kindly complete the part numbers by adding the suffix (in place of ‘c’) for the conductor type required: 0 = annealed bare copper (ABC), 1 = annealed tinned copper (ATC)
AWG | Metric
Cross Section Area (Sq. mm) | Part Number | ||||
UL 3289 | UL 3321 | UL 3173 | UL 3271 | UL 3344 | ||
21 | 0.5 | 06090101xx9c | 06090116xx9c | 06090131xx9c | 06090146xx9c | 06090161xx9c |
19 | 0.75 | 06090102xx9c | 06090117xx9c | 06090132xx9c | 06090147xx9c | 06090162xx9c |
18 | 1.00 | 06090103xx9c | 06090118xx9c | 06090133xx9c | 06090148xx9c | 06090163xx9c |
16 | 1.5 | 06090104xx9c | 06090119xx9c | 06090134xx9c | 06090149xx9c | 06090164xx9c |
14 | 2.5 | 06090105xx9c | 06090120xx9c | 06090135xx9c | 06090150xx9c | 06090165xx9c |
12 | 4.00 | 06090106xx9c | 06090121xx9c | 06090136xx9c | 06090151xx9c | 06090166xx9c |
10 | 6.00 | 06090107xx9c | 06090122xx9c | 06090137xx9c | 06090152xx9c | 06090167xx9c |
8 | 10.00 | 06090108xx9c | 06090123xx9c | 06090138xx9c | 06090153xx9c | 06090168xx9c |
6 | 16.00 | 06090109xx9c | 06090124xx9c | 06090139xx9c | 06090154xx9c | 06090169xx9c |
4 | 25.00 | 06090110xx9c | 06090125xx9c | 06090140xx9c | 06090155xx9c | 06090170xx9c |
2 | 35.00 | 06090111xx9c | 06090126xx9c | 06090141xx9c | 06090156xx9c | 06090171xx9c |
1 | 50.00 | 06090112xx9c | 06090127xx9c | 06090142xx9c | 06090157xx9c | 06090172xx9c |
2/0 | 70.00 | 06090113xx9c | 06090128xx9c | 06090143xx9c | 06090158xx9c | 06090173xx9c |
3/0 | 95.00 | 06090114xx9c | 06090129xx9c | 06090144xx9c | 06090159xx9c | 06090174xx9c |
4/0 | 120.00 | 06090115xx9c | 06090130xx9c | 06090145xx9c | 06090160xx9c | 06090175xx9c |