XLPE/PVC 3 CORE SUBMERSIBLE FLAT CABLE WITH WALL
- REACH
- RoHS
- CE
- CPR Compliant
These submersible flat cable are specially designed to provide distinguished tube like structure for the insulated cores. The wall between the cores perfectly separates them from coming in contact with each other and provides better mechanical and electrical strength compared to the traditional submersible flat cables. The knurling on the outer surface makes the cable more durable and provides improved abrasion resistance during handling and installation of these cables.
Application
These cables are mainly used in submersible pump connections. These cables are specially designed keeping in mind the tough and severe conditions in which they are used.
Construction
Conductors: Electrolytic Annealed Plain Copper, IS 8130
Insulation: Cross-linked Polyethylene (XLPE)
Core Identification: Red, Yellow (Center Core), Blue
Sheath: PVC, Type ST 2, IS 5831
Sheath Color: Black (Knurling on the width on both sides)
Technical Data
Nominal Voltage : 1100 V
Max. Operating Temperature : 90°C
Test Voltage : 3 kV for 5 Min.
Minimum Bending Radius : Fixed, 4 X Cable Ø.
Cabel Design Parameters
Cross
sectional area (Sq. mm) | No of Strands /
Max. strand dia. (mm) | Nominal
Insulation Thickness (mm) | Nominal
Sheath Thickness (mm) | Approx. overall
dimensions (W X H) (mm) | Max DC Conductor
Resistance @ 20°C (Ω/Km) | Current carrying
capacity (Ampere) |
1.5 | 22/0.3 | 0.7 | 0.9 | 12.4 x 5.0 | 12.10 | 20 |
2.5 | 36/0.3 | 0.7 | 1.0 | 14.3 x 6.1 | 7.41 | 30 |
4.0 | 56/0.3 | 0.8 | 1.0 | 16.3 x 6.9 | 4.95 | 37 |
6.0 | 84/0.3 | 0.8 | 1.1 | 18.0 x 7.2 | 3.30 | 46 |
Current Rating Conversion factor for deviating ambient temperature
Ambient temperature (°C) | 25 | 30 | 35 | 40 | 45 | 50 |
Factor | 1.16 | 1.11 | 1.06 | 1 | 0.95 | 0.88 |